“Built-in insert” sounds like one installation type. In the Modern Flames Redstone family, it is safer to read those words as two separate project routes. The current US manual defines a built-in unit as one mounted in a custom-framed wall and an insert as one placed in an existing fireplace. It also assigns a different power path to each route.
That distinction should be settled before size or flame settings. Redstone currently spans five nominal sizes, but the full RS model number controls the finished-opening row, and only three models have an official extra-wide trim branch. A listing that says only “Redstone 36” or “Redstone built-in insert” has not yet described a complete order.
“Built-in/insert” is a fork, not one installation
Modern Flames’ current fireplace catalog lists Redstone as “built-in or insert” in 26-, 30-, 36-, 42- and 54-inch sizes. The current Redstone US owner’s manual makes the fork more precise:
- Built-in mounted means the fireplace is mounted in a wall custom-framed for the appliance. The manual places this route on its hardwiring path.
- Insert mounted means the fireplace is inserted into an existing fireplace. The manual places this route on the supplied-cord and receptacle path.
Those are source definitions, not a complete installation approval. The actual wall, opening, circuit and local requirements still need the responsible people and current exact document. But the definitions are enough to prevent a seller title from mixing the built-in opening table with the insert power route.

The two drawings above are conceptual, not Redstone product drawings. On the left, the appliance and a new finished opening belong to one plan. On the right, the appliance has to enter an opening that already exists, while a separate trim decision determines what remains visible around it.
The RS number chooses the box and the opening record
The family page calls the products 26, 30, 36, 42 and 54 inches. Those are useful shopping names, not cut dimensions. The manual identifies the actual branches as RS-2621, RS-3021, RS-3626, RS-4229 and RS-5435 and publishes a labeled finished-opening row for the built-in method.
| Exact model | Nominal size | Manual finished opening for built-in, W × H × D | Standard trim described by the manual | Official extra-wide trim branch |
|---|---|---|---|---|
RS-2621 |
26 in. | 23 × 18 3/4 × 10 in. | 16mm attached; 41mm included | Listed in 5- and 7-inch versions |
RS-3021 |
30 in. | 28 1/4 × 18 3/4 × 10 in. | 16mm attached; 41mm included | Listed in 5- and 8-inch versions |
RS-3626 |
36 in. | 32 5/8 × 23 7/8 × 10 in. | 16mm attached; 41mm included | Listed in 4- and 6-inch versions |
RS-4229 |
42 in. | 38 3/4 × 26 3/4 × 10 in. | 16mm attached; 41mm included | Marked not available |
RS-5435 |
54 in. | 50 15/16 × 32 3/4 × 12 in. | 16mm attached; 41mm included | Marked not available |
The values in the third column are the manual’s finished-opening dimensions for its built-in section. They are not measurements of the visible glass, the outer trim or an existing masonry opening. Keep those labels intact when transferring the row into a drawing. The electric fireplace specifications guide separates nominal size, appliance dimensions, viewing area and required opening so that one number cannot silently replace another.
An existing fireplace needs a different record. Measure the usable cavity, tight points, insertion path and visible opening, then compare them with the exact model documents. The electric fireplace insert size guide owns that generic measurement task. This page contributes the Redstone-specific identity and trim limits; it does not declare that a model fits an opening it has not seen.
Standard trim and extra-wide trim solve different edges
The manual says the fireplace ships with a 5/8-inch (16mm) trim attached and includes a thicker 1 5/8-inch (41mm) trim. The installer may choose between them. That pair belongs to the standard product-trim decision.
The optional extra-wide sets are a separate accessory branch. Modern Flames’ official Redstone trim-options sheet names two sets for each of the first three models:
RS-2621:TK-RS26-3324orTK-RS26-3726RS-3021:TK-RS30-3824orTK-RS30-4427RS-3626:TK-RS36-4128orTK-RS36-4530
The part number matters because the sheet publishes different overall sizes and bottom-piece configurations. “Wide trim included” is therefore too vague for a quote. It might mean the included 41mm trim, an optional extra-wide set, or a merchant’s informal description of the visible face.
Write the exact part number beside the exact fireplace model and compare the accessory’s published outer coverage with the existing opening. Also confirm current availability with the manufacturer or seller before treating an older accessory sheet as stock evidence. The electric fireplace surround guide helps when “surround” might instead mean a matched frame, a mantel package or site-built finish.
The 42 and 54 branches need a stricter coverage answer
The current manual’s extra-wide-trim table marks RS-4229 and RS-5435 not available. The official Redstone insert flyer likewise limits its insert-surround sets to the 26-, 30- and 36-inch models.
That fact does not say a 42- or 54-inch Redstone can never use the insert method. The same current manual covers all five RS models and defines an insert-mounted route. What disappears for the two larger branches is the documented extra-wide trim solution.
This creates a narrow but important result:
- If the exact 42- or 54-inch appliance fits the existing opening and one of the standard trims provides the required finish, keep evaluating the insert route under the current manual.
- If the project needs an official extra-wide surround to hide the opening edges, the current Redstone documents do not provide that branch for
RS-4229orRS-5435. Pause the order or change the model, finish strategy or project.
A custom surround is not an automatic substitute. It changes ownership, material, clearances, air movement, attachment and service access. Those fields must be resolved from the exact appliance document and the appropriate design and trade scopes rather than inferred from a merchant photo.
Make the opening sketch carry the exact RS model
A Redstone drawing should be reconstructable without the search results. Put the following evidence on the same record:
- full RS model, not only the nominal size;
CUSTOM-FRAMED BUILT-INorEXISTING-FIREPLACE INSERT;- the manual’s labeled finished-opening row for built-in, or the complete measured-opening record for insert;
- 16mm, 41mm or an exact extra-wide trim-kit part number;
- hardwired or supplied-cord/receptacle path as assigned by the manual;
- current manual URL, revision information shown in the document and the date checked;
- any unresolved edge coverage, electrical, clearance or service-access question.
For a new wall, move the exact model and source drawing into the electric fireplace framing guide only after the model and route agree. For a missing or uncertain document, use the electric fireplace manual guide to verify that the covered-model list actually contains the quoted unit.
One sentence on the quote can expose most mismatches:
The project uses Modern Flames Redstone [full RS model] as a [custom-framed built-in / existing-fireplace insert]. The controlling manual and [finished-opening row / measured existing-opening record] agree. The visible edge is resolved by [16mm trim / 41mm trim / exact extra-wide kit], and power follows the manual’s [hardwired / supplied-cord] branch. [Named field] remains on hold.
Stop when four nouns disagree
The four nouns are model, method, opening and trim. “Redstone 36,” insert power, built-in dimensions and a 42-inch accessory do not become one valid package because each item is individually plausible.
A missing RS number is a model hold. A quote that never says built-in or insert is a method hold. A nominal size offered as a cut dimension is an opening hold. “Surround included” without 16mm, 41mm or a named extra-wide part is a trim hold.