The current Napoleon Entice 60 page gives two incompatible heat stories. Its key-features section says 5,000 BTU and 1,500 watts. Farther down, the specification table says 10,000 BTU and 3 kW for the same NEFL60CFH-1. That difference is too large to smooth over as rounding.
It does not make the whole Entice family unusable. The five current CFH-1 models can still be compared for body size, viewing area, minimum framing and installation relationship. It does mean that a buyer choosing the 60-inch model for the larger heat claim should pause until Napoleon or the seller identifies the controlling exact-model document or rating label in writing.
The live 60-inch page does not tell one heat story
On the live US Entice 60 product page, the conflict appears inside one official product owner, not between a manufacturer and an unrelated retailer:
- Key features: up to 5,000 BTU and 1,500 watts.
- Specification table: 10,000 BTU and 3 kW.
The current US Entice series page adds another reference point: it describes the family as producing up to 5,000 BTU and 1,465 watts at 120 volts. None of these statements proves room performance, but they should at least agree on the appliance’s electrical and heat-output class before that class drives a purchase.
For now, treat NEFL60CFH-1 as a valid size candidate and an unresolved heat-spec candidate. Do not convert the larger table value into a 240-volt assumption, a circuit plan or a promise of twice the heat.
W415-4155 keeps the CFH-1 family on one 120V ceiling
The current W415-4155 Entice manual covers NEFL36CFH-1, NEFL42CFH-1, NEFL50CFH-1, NEFL60CFH-1 and NEFL72CFH-1. Its rating-plate information places the listed family at 120 VAC with a maximum 1,465-watt input, and its electrical instructions call for a dedicated, grounded 15-amp circuit.
That 15-amp requirement is not a claim that the fireplace constantly draws 15 amps. It is the documented circuit requirement. The 1,465-watt figure is not a measured result from our own testing, either; it is the manufacturer-manual ceiling for the covered models.
If a seller says the 60-inch unit is a different 3-kW electrical configuration, ask for the exact current manual or rating-label image that covers NEFL60CFH-1. The electric fireplace manual guide explains why the model list and document revision matter more than a familiar-looking cover page.

The five sizes change the glass and opening
The number in an Entice model name is a shopping label, not every width a project needs. Three horizontal measurements have different jobs:
- Appliance width is the outer body dimension that must fit the wall relationship.
- Viewing width is the visible fire area and is the better number for judging visual span.
- Minimum-framing width is the manufacturer’s listed framing value for recessed planning. It is not permission to cut a wall without the current exact-model instructions.
| Exact model | Appliance W × H × D | Viewing area W × H | Minimum framing W × H × D | Documented relationships |
|---|---|---|---|---|
NEFL36CFH-1 |
36 × 16.94 × 5.44 in. | 32.06 × 11.94 in. | 35.13 × 16 × 6 in. | Wall mount, partial recess, full recess |
NEFL42CFH-1 |
41.75 × 16.94 × 5.44 in. | 37.81 × 11.94 in. | 40.88 × 16 × 6 in. | Wall mount, partial recess, full recess |
NEFL50CFH-1 |
49.69 × 16.94 × 5.44 in. | 45.81 × 11.94 in. | 48.88 × 16 × 6 in. | Wall mount, partial recess, full recess |
NEFL60CFH-1 |
59.69 × 16.94 × 5.44 in. | 55.75 × 12 in. | 58.88 × 16 × 6 in. | Wall mount, partial recess, full recess |
NEFL72CFH-1 |
71.69 × 16.94 × 5.44 in. | 67.75 × 12 in. | 70.88 × 16 × 6 in. | Wall mount, partial recess, full recess |
The table keeps the source labels separate. A 60-inch shopping name corresponds to a 59.69-inch body, a 55.75-inch viewing area and a 58.88-inch minimum-framing width. Substituting any one of those for another can create a wrong expectation even when the copied number is accurate.
The 36-, 42- and 50-inch models list an 11.94-inch viewing height, while the 60- and 72-inch models list 12 inches. That small vertical difference is less important than the large change in viewing width, but recording both dimensions prevents a rendering or product card from silently becoming the measurement source. The electric fireplace specifications guide provides the general method for keeping nominal, appliance, viewing and opening fields apart.
Surface mount and recessed are different electrical projects
The Entice manual separates three physical relationships: wall-mounted, partially recessed and fully recessed. They are not just three visual styles. The documented power connection changes with the relationship.
For the wall-mounted path, the manual shows the power cord passing through the wall-mount installation. For both partial and full recess, it instructs the installer to remove the power cord and complete a hardwired connection. That makes “plug-in or hardwire” an installation-dependent choice for this family, not a free option to decide after the wall is closed.
A recessed project therefore needs the exact model, current manual and electrical path aligned before framing. Use the plug-in or hardwired guide for the general ownership split, and the wall-mounted electric fireplace guide when the room is still deciding whether surface mounting fits the wall.
This page does not approve a cavity, circuit or installation. Existing wiring, local rules, required clearances, combustible materials and service access remain project-specific. If the selected relationship or power route is not written on the plan, the model decision is not ready to hand off.
Choose the width from two room measurements
Start with two room-side decisions instead of a nominal model number:
- Maximum appliance width: the space the outer body can occupy after accounting for the intended wall relationship and adjacent finish.
- Desired viewing width: the visible fire span that should relate to the wall, media feature or furniture composition.
Then choose the smallest exact model that clears both needs. For example, if the visual plan calls for at least 54 inches of viewing width, the 50-inch model’s 45.81-inch viewing area is too short while the 60-inch model’s 55.75-inch viewing area clears the visual requirement. The body still needs 59.69 inches of planned width, and a recessed route still needs its separately labeled minimum-framing record.
If the available wall width is the tighter constraint, work in the other direction: eliminate any body that cannot fit before comparing viewing spans. Do not add decorative clearance, finish build-up or manufacturer clearance to the table by guesswork. Carry the selected model into the electric fireplace framing guide with the exact current drawing when the project reaches framing.
This two-measurement choice also prevents heat claims from selecting the physical size. In the current sources, all five documented CFH-1 models share the same manual ceiling. A wider model primarily changes the appliance and viewing geometry shown here; it should not be sold to the room as a verified step-up in heat without model-specific evidence.
Make the source conflict part of the order record
For the 36-, 42-, 50- and 72-inch models, the current family data and W415-4155 provide a coherent 120-volt, maximum-1,465-watt reference path. For the 60-inch model, the live exact page’s larger 3-kW / 10,000-BTU table entry remains unresolved against that path.
Put the conflict into a written question instead of asking whether the listing is “correct”:
For Napoleon Entice model
NEFL60CFH-1sold for US installation, which current exact-model manual and rating label control the electrical input and heat output? The live product page shows 5,000 BTU / 1,500 W in key features but 10,000 BTU / 3 kW in its specification table, while W415-4155 shows the listed CFH-1 family at 120 VAC and maximum 1,465 W. Please identify the controlling document and provide the matching rating-label or manual page.
Keep the answer, document revision and model number with the order record. A reply that repeats only “Entice 60” without the NEFL60CFH-1 identity and controlling source does not close the conflict. Nor does a retailer’s wattage field establish a new electrical configuration by itself.
If the project wants the 60-inch viewing span but does not depend on the larger heat claim, the physical choice can continue using the documented body, viewing, framing and installation values. If the purchase depends on 3 kW or 10,000 BTU, it remains on hold. Until exact-model evidence reconciles the sources, the model can remain a 60-inch visual/fit candidate—but not a verified 3kW or 10,000-BTU heater.