Napoleon Elevation Electric Fireplace: Electric, X or Gas?

Elevation is not the model number. In Napoleon’s current US lineup, a standard Elevation Electric carries NEFB36H-MF or NEFB42H-MF. An Elevation X Electric carries NEFB36LCD-MF or NEFB42LCD-MF. A gas Elevation uses a different appliance, fuel system and installation manual. If a quote says only “Napoleon Elevation 36,” it is not specific enough to approve an order or a framed opening.

The suffix changes more than the flame presentation. The current standard-electric manual requires hardwiring and lists a 16 1/4-inch minimum framing depth. The current X Electric manual includes a supplied cord that can be removed for hardwiring and lists 16 7/8 inches. Both electric families support 120/240V and list up to 1465/2930W on a dedicated 15A grounded circuit, but that shared electrical headline does not make their build details identical.

Generic fireplace model plate branching to standard electric, LCD electric and gas installation paths
The family name starts the search; the exact model code chooses the appliance, utilities and manual.

Elevation is the family; the suffix is the product

The quickest way through the product names is to ignore the lifestyle copy for a moment and read the code:

  • H-MF in NEFB36H-MF or NEFB42H-MF points to the standard Elevation Electric. Napoleon describes this family as a deep built-in electric fireplace with triple-layer projected flame effects and split-oak logs.
  • LCD-MF in NEFB36LCD-MF or NEFB42LCD-MF points to Elevation X Electric. Its defining hardware is the rear LCD, which displays gas- or wood-style flame video; the product also includes built-in speakers.
  • A gas Elevation or Elevation X is not another control mode inside either electric appliance. It is a direct-vent gas product with its own rating plate, supply, venting, clearances, options and manual.

This distinction matters before size. “36” narrows the nominal opening class, but it does not distinguish NEFB36H-MF from NEFB36LCD-MF or a 36-inch gas model. A seller’s shortened title can therefore point to three materially different projects.

The same discipline applies elsewhere in the brand. A Napoleon Entice, for example, belongs to a different, much shallower product family; our Napoleon Entice model guide owns that decision. Do not use an Entice dimension or feature to fill a blank in an Elevation record.

Four electric model codes lead to two different builds

The table uses Napoleon’s current US product owners and the current manuals available on September 14, 2026. Dimensions are minimum rough-framing width × height × depth, not the appliance face, viewing area or finished trim.

Exact model codes determine the display platform, connection method and minimum framed depth
Exact electric model Product identity Visual system documented by Napoleon Supply and maximum input Connection in current manual Minimum rough opening
NEFB36H-MF Standard Elevation Electric 36 Triple-layer projected flame effect; split-oak log set 120/240V AC; 1465/2930W; dedicated 15A grounded circuit Hardwire required 39 3/4 × 35 9/16 × 16 1/4 in
NEFB42H-MF Standard Elevation Electric 42 Same standard-electric platform 120/240V AC; 1465/2930W; dedicated 15A grounded circuit Hardwire required 45 3/4 × 39 9/16 × 16 1/4 in
NEFB36LCD-MF Elevation X Electric 36 Rear LCD with gas- and wood-style video, layered effects and speakers 120/240V AC; 1465/2930W; dedicated 15A grounded circuit Supplied cord; current manual also documents qualified hardwiring 39 3/4 × 35 9/16 × 16 7/8 in
NEFB42LCD-MF Elevation X Electric 42 Same X Electric LCD/speaker platform 120/240V AC; 1465/2930W; dedicated 15A grounded circuit Supplied cord; current manual also documents qualified hardwiring 45 3/4 × 39 9/16 × 16 7/8 in

The standard rows come from Napoleon’s Elevation Electric series page and installation manual W415-10001346, revision B-0. The X rows come from the current Elevation X Electric series page and installation manual W415-10003440, revision D-0.

These are source records, not a claim that the four products perform equally. Flame appearance, speaker quality, heater noise and app reliability require a different kind of evidence than an installation manual. The matrix answers the part that can be settled before purchase: which hardware family, utility path and opening the exact code requires.

Choose standard Electric or X before you compare flame settings

Elevation X is not a decorative trim package added to the standard unit. The current X product pages identify the rear LCD and built-in speakers as part of the appliance. The standard Electric instead uses Napoleon’s triple-layer projection system. That difference should carry the first comparison.

Choose the standard branch when the standard projected-flame system is the product you have actually evaluated and the quote carries an H-MF code. Choose the X branch only when the LCD gas/wood video and speaker layer are features you deliberately want and the quote carries an LCD-MF code. A showroom label that says “Elevation with app” does not settle the choice because both current electric families advertise remote, mobile-app and voice-control options.

This is why feature-count shopping can misfire. App control is shared; the image-generation hardware is not. If connected control matters, compare what remains usable without the service in our smart electric fireplace guide, then return to the exact Elevation code. Do not let the common app badge erase the more permanent display and installation differences.

Size comes next. The 42-inch models increase the minimum width and height over their 36-inch siblings. The choice should come from the available wall, desired viewing proportion and verified finish plan—not from the assumption that “42” is only a wider version that can drop into a 36 opening.

The current manuals disagree by five-eighths of an inch

The width and height pairs line up by nominal size in the manuals inspected. The minimum depth does not:

  • Standard Electric 36 and 42: 16 1/4 inches
  • X Electric 36 and 42: 16 7/8 inches
  • Difference: 5/8 inch

That 5/8 inch is small enough to disappear in a product-card summary and large enough to matter after studs, interior lining and finish thickness have been committed. It is also why the manufacturer’s current manual should sit beside the drawing. Our electric fireplace framing guide explains how to translate the model-specific minimum opening into a buildable plan without confusing appliance, viewing and trim dimensions. The broader specification-field guide defines those dimension labels.

The electrical branch also differs. Standard-manual revision B-0 says it is necessary to hardwire NEFB36H-MF and NEFB42H-MF, with a qualified electrician connecting the unit to household wiring. X-manual revision D-0 describes a provided cord and tells the electrician to disconnect it if hardwiring is chosen. The current X product pages likewise describe plug-in or hardwired use. Therefore “120/240V” alone is not a complete installation instruction.

Both manuals list 120/240V AC, maximum 1465/2930W and a dedicated 15A grounded circuit. Freeze the chosen voltage before construction because the manual’s conductor and terminal steps differ. Do not infer the branch from the 10,000-BTU marketing line. Use the model manual and electrical plan; the site’s 240-volt electric fireplace guide owns the wider power-path decision.

Manual revision belongs in the record. A saved retailer specification or older PDF may remain online after an owner document changes. If the model code and manual cover do not match, stop and retrieve the correct file through the model-bound fireplace manual guide before transferring any number to a quote or drawing.

“Choose fuel later” is a project option, not a gas-ready certificate

Napoleon promotes the Elevation family with shared-framing language: frame now and choose electric or gas later. That is useful design intent, but it answers only part of a future-fuel decision.

An opening can match while the project is still not ready for gas. A current Elevation X gas product has its own direct-vent system, gas-supply requirements, clearances, heat-management choices, finishing rules and accessory combinations. Those fields do not appear in the electric manual because they do not belong to the electric appliance. A gas model page also carries gas-specific installation manuals and support documents.

If gas is a genuine future possibility, put the exact candidate gas model and its current manual into the construction set before the wall closes. Ask the responsible hearth professional and trades to reconcile at least:

  • the gas model’s minimum enclosure and finish schedule;
  • approved vent route, termination and service access;
  • gas-supply route and shutoff location;
  • combustible clearances, mantel/television conditions and any heat-management option;
  • which parts of the electric opening can remain and which utilities are fuel-specific.

If those items are absent, label the plan electric-only today; future gas readiness not established. That wording protects the option without pretending it is solved. If the project is still choosing between fuel paths now, use the gas-versus-electric fireplace guide before selecting the Elevation appliance.

The current manual-depth comparison adds another reason not to treat “same framing” as a universal value. Even the two electric Elevation branches inspected here list different minimum depths. A gas option deserves its own exact reconciliation, not a stronger assumption.

Put one exact line on the quote and the construction set

A usable Elevation line contains more than the brand, family and nominal size. For example:

NEFB36LCD-MF — Elevation X Electric 36 — electric — manual W415-10003440 D-0 — 240V hardwired — dedicated 15A grounded circuit — minimum rough opening 39 3/4 × 35 9/16 × 16 7/8 in — future gas option: not established.

Change every field to match the actual project. A 120V cord-connected X installation would say so. A standard Electric 42 record would cite W415-10001346 B-0, hardwiring and the 45 3/4 × 39 9/16 × 16 1/4-inch opening. A real gas-ready plan would name the exact gas model and its manual rather than replacing the last phrase with “same framing.”

Approve the electric purchase only when the quote’s model code matches the product page and current manual, the chosen voltage and connection method appear on the electrical plan, and the three opening dimensions appear on the framing drawing. If the document says only “Napoleon Elevation,” or if an H-MF/LCD-MF suffix, manual revision or future-gas owner is missing, the correct result is not a guess. It is a hold before the wall or order makes the ambiguity expensive.